The most common pool timer used for inground pool pumps is the Intermatic time clock. "name": "Davy Merino",
I have a Model T104P and have a new green on tripper attached. Ive seen it happen from lightning strikes, or insect infestation. The circuit is protected by two ganged breakers. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Sometimes its way quick just to replace it rather than spend hours troubleshooting. And does the switch look worn, where the tripper engages? There is a second switch between the breaker and the timer. I manually turn it on timer is running, it will trip pump OFF. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. Pool pump timers can last up to 20 years, depending on the model. Also be sure that the front dial is engaged with the gear located behind the dial. Inspect the tripper portion, if it looks rounder or worn, replace them. How can I fix this? the ground wire? how should I lubricate those? This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. I replaced the pump and still nothing is moving. If you pull out on the clock dial, you can turn it to set the current time, aligning with the silver down-arrow, located at 6 oclock. It is still moving and it will trip off but not on. be sure the pins are pushed onto the edge of the dial fully. Now, Im going to order some additional timer clips. Also, once it reaches the tripper, the gears in the window no longer move. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. You may need to adjust the meshing of the timer motor gear so it runs the clock. Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. If power is coming to the timer motor, you will clearly see the gears moving through the small window. Pull the timer out and turn it to the correct time. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Hi Doug, Check the wiring. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. That should quiet it down. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. The problem is the 'off' tripper. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Please advise. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). Check the motor, and be sure the label is not printed 50 hz. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. How about the GFCI outlet TEST button, is it tripped? Pool pump comes on fine with the on dog, but wont turn off. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting Im ready to send my back for a replacement. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Thank you for choosing Intermatic! Then after a bit, the pump restarts. When I put the new one on, the trippers do not work. Hello. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
With the power switched off at the breaker, take out the main part of the timer and carefully inspect the gears for obstructions and missing teeth. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. Perhaps you had a power outage during the night? Ft. 750 Joshua Dr, Hollister, CA 95023. Reasons Why Pool Timers Stop Working 1. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . Open following links to identify timer and then add a comment. Any advice? The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. Any suggestions? Date Listed: 18/02/2023; . Ill do the same. So out comes the soldering gun and the shrink wraps and that did the trick. Could also be grit or insects inside of the gears of the clock motor. But no gears or any sound. Any help is greatly appreciated. When you flip the switch does it separate and reconnect the tabs? I had to order new trippers as mine have been straightened too many times. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. And when switched on, power to the load terminals? On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. If after verifying you have power to the timer, then check these things to further troubleshoot. Simply screw it back into place until its snug. Intermatic timers are a great addition to your pool set up but they can go wrong. Just turn the timer wheel until the correct time of the day is aligned with the timer marker that is mounted in front of the wheel. The old "off" tripper was fractionally bent. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Push down on the timers until they snap into place. Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. Is there anything else I can do or do I need to get a new one? Timer not tripping pump on. This morning the customer said it wasn't turning off. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Some of the replacement motors make it past quality control with the incorrect gear setup. "address": "",
The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. Everythings OK now, unit works just fine. Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. If your pool pump timer is beyond repair, call a professional to replace it. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. And Ive noticed lately that the ON is not functioning all the time. {
Wired correctly, #10 wire, nothing. When the trippers are done up, you shouldnt be able to move them with your hands. Thanks for the suggestions.. But my new timer will not work either. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! Video of the Day Trippers Leave the paper inside your timer box so that you do not mistakenly misplace it. We may earn a small commission. how do I check the manual over ride switch to see if it is off? Im going to try inspecting the back of the timer to see if a wire go knocked loose or something. Hi Casey, perhaps the cord or wires are broken? Morgan Burley any suggestions about how i might avoid another situation like the above would be appreciated. Also known as an RCD (residual current device) in Australia and the UK. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. I looked to see if the gears on the timer are running. We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. Clock not turning or making any sound. Stupid third question, but does the ON tripper say ON? Hi Tom, sure you can spray some 3-in-1 or wd-40 on the motor gears, just depress the tab at 12 oclock and pop out the mechanism, to target the oil onto the gears. Now remove the terminal cover on the timer. "@type": "ImageObject",
Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. we purchased the house 5 years ago so not sure how old the timer is? Turn in either direction and align the exact time-of-day on . The timer not working is for the pump. Tighten down all brass screws securely, to hold all wires firmly in place. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. I made sure the trippers were fully inserted and tight. Now try to jiggle it on and off. 1. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. If its loose, grab a screwdriver and tighten it up. This is the first step to confirm if there is power or not. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. "@type": "Person",
Assuming the wiring is all correct. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
You will want to make sure the manual switch under the timer wheel is pushed to the on position. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Help! Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Until it came in, I manually turned on and the tripper turned it off. Look to see if the clock is set to the correct time. We are on our third timer. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. Repeat the process for the "on" pin. Is this a bad timer mechanism or loose wire? Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. Yes, likely a short to ground. If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Trippers are not installed properly Re-install trippers on dial 2. Hi Rhomell, are you sure you got the correct trippers? Please let me know if you find the solution! Replace a new T104. The mechanism for the off tripper doesn't work at all when manually depressed. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. "dateModified": "1/10/2020",
I believe its the manual on/off switch that is the problem. Turn the manual on/off switch. Your email address will not be published. Or be loose and not making good contact. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. It was always fine before. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! Sound right? "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
Basically 12 real life hours equals about 14 on the timer. You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. My time clock has an ant infestation! You can replace it but its really just easier to replace the entire mechanism. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Watch these tips and tricks before replacing it. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. The terminals on the wires aren't tight. Flip off the breaker. All Rights Reserved. There's an issue with the wiring between the circuit breaker and the timer. Is this broken? Is there a control board, PCB in the panel that could have problems? Thanks again for your help. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor.